  • Indoor Carbon Monoxide (CO) and Carbon Dioxide (CO₂) Datalogging Meter

    Extech CO260 - Extech Instruments Corporation

    The Extech CO260 monitors indoor air quality for Carbon Monoxide (CO) and Carbon Dioxide (CO₂) levels. In high concentrations these gases can affect the health and well-being of people and pets. Monitor CO₂ levels in schools, office buildings, greenhouses, factories, hotels, hospitals, transportation lines and anywhere that high levels of carbon dioxide are generated. Common areas to monitor CO levels include boiler rooms, warehouses that use propane and gasoline-powered for lifts, boats, planes, RVs, and manufacturing plants. The CO260 also measures air temperature/relative humidity and calculates dew point/wet bulb temperatures. It can datalog manually up to 99 readings with internal memory or continously up to 32K readings with included software.

  • Clock Drivers

    Pulse Instruments

    Multiple timing signals ("clocks") are required by CCDs, IR FPAs, and some CMOS image sensors to transport electrical charge across the array to a sense amplifier for conversion into image data. Pulse Instruments offers a line of "clock drivers" for generating these timing signals. The parameters of these clocks (clock rate, pulse width, pulse amplitude, rise- and fall-times, etc.) greatly influence the behavior and performance of the imaging device. Our products take logic-level inputs from a pattern generator and allow the user to adjust the output parameters to suit their device and testing requirements. Clocks can be "tweaked" in real-time to determine optimal operating parameters for a particular device, or else programmed in accordance with a test plan for automated production test.

  • PC Based Comprehensive Test Setup for Luminaires

    SCR ELEKTRONIKS

    Our zest for innovation has resulted in continuous upgrades in the existing line of products. Till now we used to manufacture 3 different equipments for Driver, MCPCB and Luminaires Component testing. We at SCR Elektroniks have developed our comprehensive tester to incorporate all the 3 systems in a single bench. Here in this tester one can test all the three DUT in a single bench. Since all the 3 testing procedures have many tests in common, we have incorporated all the tests in a single bench such that testing of Luminaire driver, Luminaire PCB and Final Luminaire set is performed in single test bench. Only these tests are performed over the DUT else other are disabled for them.

  • MicroLite USB Data Loggers

    Fourier Systems

    The family of MicroLite USB data loggers includes six models covering temperature, humidity, current and voltage measurements, providing the ideal solution for a wide range of industrial applications. Combining innovation with simplicity, the MicroLite product line offers cost effective logging, with rich functionality in a compact design, direct USB connection, multi-trip usage, and high measurement accuracy and resolution. Real-time sensor readings with a corresponding time stamp are clearly displayed on the logger’s LCD screen, incorporating alarm thresholds. The logger is designed for low power consumption to extend battery life and reduce the time between battery replacements. The comprehensive MicroLite range allows you to select the device most appropriate to your mission-critical application.

  • Broadband Power Amplifier

    Panda Microwave Limited

    Panda Microwave design, manufacture, and support a wide variety of Power Amplifier. RF amplifiers product line from Panda Microwave consists of low noise amplifiers, Power Amplifier Module and Solid State High Power Amplifier. Our Power amplifiers cover frequency range from 100MHz to 50GHz and used Thin-film Technology. Our low noise amplifiers have superior noise figure numbers and a variety of models. Gain block low noise amplifiers provide all around gain where noise is not critical. High power amplifiers system equipment is available with either manual or digital control interfaces, power capacities up to 100W pulse power.

  • [5kV AC] Hipot Tester, Rise/Fall-Time Control Function Equipped

    TOS5200 - Kikusui Electronics Corp.

    TOS5200 is designed for AC Hipot Test with 500 VA capacity and 200 mA short circuit current output capability. Equipped with the PWM amplifier, the TOS5200 can provide a stable & reliable output without being affected by ACpower line. Therefore, it is a perfect solution for electronic equipment or devices complied to IEC, EN, UL, VDE andJIS etc. requirement.As TOS5200 covers most of features of our upper class model for AC Hipot Test, it achieves thesuperb cost / performance ratio for those who need 200 VA or 500 VA capacity, or both. Also, as it equips the Interlockfunction together with other safety features, operator can carry out the test with higher current value in safe.

  • Power Supply Testers

    Qmax Test Technologies Pvt. Ltd.

    Power Supply Tester is an integrated package of hardware such as AC/DC Power Sources, DC Loads, Noise Measurement Unit, and DMM etc configured as per user applications, which makes it suitable for testing wide range of Power Supplies and provide economic solution for testing AC/ DC and DC/DC power supplies and converters. The Power Supply Boards that passed in the first level of screening for Go-No Go tests will undergo a second level testing. The second level of testing measures all the key parameters of the power supply such as line regulation, load regulation, efficiency etc and check whether the results are within the mentioned limit, if not declare the UUT (Power Supply Board Under Test) as a failed one.

  • Analogue (1kV below) Insulation Tester

    2132 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test. ● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.

  • Analogue (1kV below) Insulation Tester

    1832 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.

  • PXI-6723, 13-Bit, 32-Channel, 800 kS/s PXI Analog Output Module

    778998-01 - NI

    13-Bit, 32-Channel, 800 kS/s PXI Analog Output Module—The PXI‑6723 delivers low-cost, high-density analog outputs to meet a wide range of applications, such as stimulus-response, signal simulation, waveform generation, and actuator stimulation. In addition, the device provides eight 5 V TTL/CMOS digital I/O lines; two 24‑bit, 20 MHz counter/timers; and digital triggering and external clocking capabilities. The PXI‑6723 can replace several kinds of instruments, including stand-alone proportional integral derivative (PID) controllers, low-speed arbitrary waveform generators, and function generators. You can control each data point for each channel to define common waveforms, such as square, sine, or sawtooth, as well as complex waveforms.

  • Imbedded A5 Processor Test Interface

    Advanced Microtechnology, Inc.

    Advanced Microtechnology has extended the application of its Optimum product line with theintegration of ARC5 imbedded test functions. Up to 40 controllers may be independently powered and monitored for functionality using the process test interface of the Optimum WinAOS application. Each part may have 2 separate biases featuring both current and voltage monitoring. Independent test is implemented through a standard JTAG interface. A separate serial clock and command interface may be used if required to provide device initialization sequences. JTAG control is muxed to each part through the use of an independent clock for each part. All of the ARC processor registers and memory space may be tested through the JTAG I/O.

  • Event Detectors

    105/106 Series - Analysis Tech Inc.

    The 105/106 Series Event Detectors are the most versatile Event Detectors in the product line. These Event Detectors monitor the electrical resistance of up to 128 simple continuity loops, each comprised of single or multiple specimens under test. Each test specimen is continuously monitored while a selectable DC sense current is passed through each channel test-loop; resistance changes exceeding the selected threshold are recorded as an event. Minimum Event Duration, Channel Current, and Threshold Voltage settings can all be independently configured. 105 and 106 Series instruments are electrically identical, with the difference simply that the 105 offers four, 32-channel board slots and the 106 offers only one. Thus the 128-105 is equivalent to four 32-106 Event Detectors.

  • For Windows 3.0

    Smith Chart - Antenna Design Associates, Inc.

    Smith Chart 3.0 is a Windows-compatible software package for the analysis and design of transmission line circuits, impedance matching problems, and transistor amplifier design. Some of the new features of version 3.0 include the following:32-bit compiled code, resulting in fast executioncompletely redesigned user interfaceautomation of basic Smith chart operationsdesign of impedance matching networksplotting of up to two Smith chart data setsplot amplifier stability circlesplot amplifier constant gain circlesplot rotated 1 + jx circlelist or save data setsuse impedance, admittance, or reflection coeff.print chart or full windowcopy chart or full window to clipboardset colors of data points, cursors, backgroundonline help for Smith Chart 3.060 page User Manual, with Smith chart tutorial

  • I²C/SPI Interface Device

    NI

    The I²C/SPI Interface Device is a master or slave interface for inter-integrated circuit (I²C), or master interface for serial parallel interface (SPI) devices. With plug-and-play USB connectivity, the I²C/SPI Interface Device is a portable solution to communicate with consumer electronics and integrated circuits. The I²C/SPI Interface Device can be physically located more closely to I²C/SPI devices than PCI interfaces, reducing I²C bus length and minimizing noise problems. The I²C/SPI Interface Device supports I²C rates up to 250 kHz and SPI rates up to 50 MHz, and it also includes eight general-purpose digital I/O lines for a variety of applications, such as configuring the address of I²C devices or toggling LEDs.

  • Linear regulated power supply with thyristor pre-regulation

    NTN - FuG Elektronik GmbH

    High efficiency Short circuit proof and unlimited operation with full current in short circuit condition voltage and current regulation with automatic and sharp transition; control mode indicated by LEDs Voltage and current setting with 10-turn potentiometers with precision scale; the adjusting knob can be locked 4 digit DVM for voltage and current (for table-top models) Sense terminals for the compensation of voltage drop on the load lines. The nominal voltage always refers to the output terminals Parallel and series connection possible Suitable for inductive and capacitive loads for 700 W nominal power and higher, limitation of inrush current on switching on Interlock loop to monitor the external load and internal loop as a standard for three phase units Elapsed-hour meter as a standard for three phase units